Order before 5pm for next day delivery
Free delivery on orders over £50+vat
Buy now pay later with
Skip to content

Elga P51 7018 Unalloyed Drypac Electrodes

Grouped product items
Position Product Code Price Qty
ELGA P51 DRYPAC ELECTRODES 2.5MM 2.0KG 71512504ELG 77415
£139.46 £116.22
5 In Stock
Check stock
ELGA P51 DRYPAC ELECTRODES 4.0MM 2.5KG 71514004ELG 77417
£109.94 £91.62
Out of stock - Preorder now
ELGA P51 DRYPAC ELECTRODES 3.2MM 2.5KG 71513204ELG 77416
£147.02 £122.52
3 In Stock
Check stock
No results found, reset search to see all options

Order before 5pm on Monday to Friday for Next Working Day Delivery on stocked items - exclusions apply

Spread the cost for up to 6 months interest free

Free delivery on orders over £50 +vat

P51 is a basic-coated low hydrogen AC/DC electrode designed for welding mild and higher strength steels.

    It combines strength and toughness and is particularly suitable for heavily restrained sections where there can be risk of cracking due to weld stresses.

    With its excellent general operability and good positional welding characteristics P 51 is often used for pipe welding.

 

     It operates without difficulties on both primer-treated and rusty material.

 

    The electrode produces a finely rippled bead surface and smooth transition with the base material.

 

    This together with the exceptionally good slag detachability, even in root runs, gives P 51 superior radio graphic quality.

    Classification

EN 499 E 46 4 B 32 H5

EN ISO 2560-A E 46 4 B 32 H5

AWS A5.1 E 7018-1H8

Coating type:  Basic

    Welding current:

    DC - (+), AC OCV ³ 70 V

    For root passes: DC -

    Hydrogen content / 100 g weld metal

     £ 5 ml

    Metal recovery:

    120%

    Redrying temperature:

    350 °C, 2h

    Mechanical properties

                                      Specified        Typical           PWHT Typical

    Yield strength, Re:         460 MPa           560 MPa         520 MPa

    Tensile Strength, Rm:    530-650 MPa     600 MPa         600 MPa

    Elongation, A5              22%                  25%                26%

    Impact energy, CV:       -46 °C    · >27 J    -46 °C    · 30 J